香蕉人妻av久久久久天天-色午夜一av男人的天堂-国产精品亚洲精品日韩已满十八小-久久精品国产9久久综合-欧美 日韩 亚洲 精品二区

Comparison table of the relationship between valve size and medium velocity

Column:Technical article Time:2019-06-22
It is well known that the flow rate and velocity of the valve mainly depends on the size of the valve, but also with the valve structure type of the resistance to the medium...

It is well known that the flow rate and flow rate of the valve mainly depends on the size of the valve, and the valve structure type of the resistance to the medium, at the same time with the pressure of the valve, temperature and the concentration of the medium and other factors have a certain internal relationship.Valve flow area and flow velocity, flow rate has a direct relationship, and flow rate and flow are interdependent two quantities.When the flow rate is constant, the flow rate is large, the flow area can be smaller;Small velocity, the flow area can be larger.On the contrary, the flow area is large and the velocity is small.The runner area is small and the velocity is high.

 

1, the flow rate of the medium is large, the valve diameter can be small, but the resistance loss is large, the valve is easy to damage.High flow rate, the flammable and explosive media will produce electrostatic effect, resulting in danger;The flow rate is too small, inefficient, and uneconomical.For high viscosity and explosive medium, should be a small flow rate.The flow rate of oil and liquid with high viscosity is selected according to the viscosity, generally 0.1 ~ 2m/s.

2. Generally speaking, the flow rate is known and the flow rate can be determined by experience.Nominal size of valve can be calculated by flow rate and flow rate.

3, the valve size is the same, its structure is different, fluid resistance is not the same.Under the same conditions, the greater the resistance coefficient of the valve, the more fluid flow through the valve velocity, flow rate drop;The smaller the valve resistance coefficient is, the less the flow rate and flow rate decreases through the valve.

 

Common flow rates of various media are shown in the following table:

Fluid nameConditions of use
Velocity(m/s)
Saturated steam
DN>200
DN=200~100
DN<100
30~40
25~35
15~30
Superheated steam
DN>200
DN=200~100
DN<100
40~60
30~50
20~40
Low pressure steamρ<1.0(Absolute pressure)15~20
Medium pressure steamΡ=1.0~4.0(Absolute pressure)20~40
High pressure steamΡ=4.0~12.0(Absolute pressure)40~60

Compressed gas
Vacuum
Ρ≤0.3(Gage pressure)
Ρ=0.3~0.6(Gage pressure)
Ρ=0.6~1.0(Gage pressure)
Ρ=1.0~2.0(Gage pressure)
Ρ=2.0~3.0(Gage pressure)
Ρ=3.0~30.0(Gage pressure)
5~10
8~12
10~20
10~15
8~12
3~6
0.5~3
oxygen
Ρ=0~0.05(Gage pressure)
Ρ=0.05~0.6(Gage pressure)
Ρ=0.6~1.0(Gage pressure)
Ρ=1.0~2.0(Gage pressure)
Ρ=2.0~3.0(Gage pressure)
5~10
7~8
4~6
4~5
3~4
Gas 2.5~15
Semi water gasΡ=0.1~0.15(Gage pressure)10~15
Natural gas 30
NitrogenΡ=5~10(Absolute pressure)15~25

ammonia
vacuum
Ρ<0.3(Gage pressure)
Ρ<0.6(Gage pressure)
Ρ≤2(Gage pressure)
15~25
8~15
10~20
3~8
Acetylene water 
30
5~6
Acetylene water
ρ<0.01(Gage pressure)
ρ<0.15(Gage pressure)
ρ<2.5(Gage pressure)
3~4
4~8
5
chlorine
Gas
liquid
10~25
1.6
氯化氫
氣體
液體
20
1.5
Liquid ammonia
Vacuum
Ρ≤0.6(Gage pressure)
Ρ≤2.0(Gage pressure)
0.05~0.3
0.3~0.8
0.8~1.5

Sodium hydroxide
Concentration 0~30%
Concentration 30%~505
Concentration 50%~73%
2
1.5
1.2
Sulfuric acid
Concentration 88%~93%
Concentration 93%~100%
1.2
1.2
HCl 1.5
Water has a similar viscosity to liquids
Ρ=0.1~0.3(Gage pressure)
Ρ≤1.0(Gage pressure)
Ρ≤8.0Gage pressure)
Ρ≤20~30(Gage pressure)
Heat network circulating water, cooling water
0.5~2
0.5~3
2~3
2~3.5
0.3~1
Water has a similar viscosity to liquidsPressure backwater0.5~2
Water has a similar viscosity to liquidsNo pressure backwater0.5~1.2

Tap water
DirectorΡ=0.3(Gage pressure)
BranchΡ=0.3(Gage pressure)
1.5~3.5
1~1.5
Boiler feed water >3
Steam condensate 0.5~1.5
CondensateGravity0.2~0.5
Hot water 2
Sea water, slightly alkaline water
Ρ<0.6(Gage pressure)
1.5~2.5

Note: the unit of DN value is mm;Ρ value unit is: MPa.


Examples:
 

The resistance coefficient of gate valve is small, only within the range of 0.1 ~ 1.5.Gate valve with large diameter, the resistance coefficient is 0.2 ~ 0.5;Shrinkage gate valve resistance coefficient is larger.

 

The resistance coefficient of globe valves is much larger than that of gate valves, generally between 4 and 7.Y-type globe valve (direct flow) has a small resistance coefficient between 1.5 and 2.Forged steel globe valve resistance coefficient is large, even up to 8.

 

The resistance coefficient of the check valve depends on the structure: swing check valve is usually about 0.8 ~ 2, in which the multi-lobe swing check valve has a larger resistance coefficient;Lift check valve resistance coefficient, up to 12.

 

Plug valve resistance coefficient is small, usually about 0.4 ~ 1.2.

 

The resistance coefficient of diaphragm valve is generally around 2.3.

 

Butterfly valve resistance coefficient is small, generally within 0.5.

 

Ball valve resistance coefficient is small, generally around 0.1.

 

Remark: the resistance coefficient of the valve is the value when the valve is fully open.

 

The selection of valve size should take into account the machining accuracy and dimension deviation of the valve, as well as other factors.Valve size should be adequate, generally 15%.In practice, the size of the valve varies with the size of the process line.


Knowledge: valve size and inch comparison table valve size (DN) and diameter comparison table


主站蜘蛛池模板: 日韩电影一区二区三区| 潮喷大喷水系列无码| 色偷偷一区二区无码视频| 非洲人与性动交ccoo| 97精品久久天干天天天按摩| 激情第一区仑乱| 99精品视频在线在线观看视频| 久久天天躁夜夜躁狠狠 ds005.com| 中文无码日韩欧| 无码人妻少妇伦在线电影| 欧美va天堂在线电影| 一本一道精品欧美中文字幕| 欧美乱妇狂野欧美在线视频| 日日夜夜撸啊撸| 大地资源在线观看官网第三页| 国产精品爽爽久久久久久无码| 国产+日韩+另类+视频一区 | 日本久久精品一区二区三区| 久久免费精品视频| 国产欧美亚洲精品a第一页| 国产av天堂无码一区二区三区| 在厨房拨开内裤进入在线视频| 亚洲国产人成自久久国产| 中文字幕一区二区人妻| 久久国产乱子伦免费精品| 国产亚洲精品自在久久| 3d动漫精品啪啪一区二区免费 | 久久无码人妻一区二区三区午夜| 久久久天堂国产精品女人| 欧美饥渴熟妇高潮喷水水| 色诱视频在线观看| 国产v综合v亚洲欧美久久| 久久综合五月丁香六月丁香| 国产精品无码久久久久| 开心久久婷婷综合中文字幕| 美女视频黄是免费| 久久精品娱乐亚洲领先| 亚洲精品无码专区在线| 春药按摩人妻弓中文字幕| 亚洲成在人线在线播放无码vr| 日韩av激情在线观看|